| The DNP Standard color Viewer for HDTV is a light source which enables you to evaluate and adjust video and still cameras. With its high-frequency Fluorescent lighting method, it handles images without flicker. |
 |
|
 |
| Light source: |
DNP Standard color Viewer lamp
(Four 15W dedicated fluorescent tubes are used) |
| Power supply: |
AC100V 50、60Hz |
| Lighting method: |
High Frequency lighting method 20KHz |
| Color rendering: |
Over 90% rendering evaluation-point for each color |
| Color temperature: |
(Measured by Minolta CL-200) |
| Operating temperature: |
10~40℃ |
| Operating humidity: |
Below 80%(avoid dew) |
| Major diameter dimension: |
490W×380H×150D m/m |
| Luminance plane dimension: |
272W×153H m/m |
| Color chart dimension: |
310W×200H m/m |
| Power consumption: |
110W |
| Weight: |
10kg |
|
 |
 |
 |
| HDF-51F |
|
|
 |
| The characteristics according to the Viewer Luminance plane |
 |
| Product Type |
Lamp |
Color Temperature |
Luminance |
Color matching shift |
| HDF-51F |
FL15D-EDL-56K |
5100K±300 |
Over 3500cd/m2 |
Within 5% |
|
 |
| *The specification may change without notice |
 |
|
 |
| 【1】 |
Before using the product: |
 |
|
Power supply |
 |
AC 100V, 50/60Hz shared |
| Light source |
 |
15W DNP Standard color Viewer Lamp (4) |
| Power consumption |
 |
110W |
|
 |
| 【2】 |
Using the DNP Standard Color Viewer for HDTV |
 |
|
(1) |
Plug the power cable of the product into AC100V |
|
|
| 【Precautions】 |
Do not connect any power supply other than AC100V
If the other power supply connected by accident, the inverter inside will burned out |
|
|
(2) |
Turn on the power switch |
|
(3) |
Lamp lights: the lamp light will stabilised after 15 to 20 minutes at the room temperature(20℃) |
|
(4) |
If the lamp does not lit, call for Service Office for the confirmation as described on other documents. |
|
(5) |
To suspend snaking of the lamp, press power switch 3 to 4 times [as ON/OFF]. |
|
 |
| 【3】 |
If the light does not lit |
 |
|
Call for Service Office to confirm the following: |
|
(1) |
AC 100V supplied to the wall socket. |
|
(2) |
Plug the product into the wall socket. |
|
(3) |
Turn the power supply switch of the product ON |
 |
|
|
 |
 |
|
Still the lamp does not lit: Consider the following: |
 |
|
|
 |
 |
|
(1) |
Two of the viewer lamps lit simultaneously, one of the fuses of the inverters has blowouts. |
|
(2) |
Four of the viewer lamps does not light means that each of the fuses of the two inverters has blowouts. |
|
|
| 【Precautions】 |
The above occurs if the applied power supply is not AC 100V.
Fuse bum out cause internal burnout of inverter. The burned inverter needs to replace. |
|
|
 |
| 【4】 |
How to replace the lamp and keep it clean |
 |
|
Place the Viewer on the flat table, and plug out the power supply cable from the wall socket.
Remove the used device in the following order: |
|
(1) |
Unfasten the four of grub screws on the top frame. |
|
(2) |
Pull up the upper frame. |
|
(3) |
Remove he glass plate and acrylic plate. |
|
|
| 【Precautions】 |
Glass plate easily breaks and may hurt your hands and fingers.
Handle the edge of the plate with care not to scratch. |
|
 |
|
◆Replacing the lamps: |
|
(1) |
When the lamps used over 2,000 hours or one year, it needs to replace. |
|
(2) |
The socket of the lamp has a spring inside, press it toward one-way. |
 |
|
◆Cleaning the device: |
|
(1) |
Impregnate alcohol to gauze then apply it onto the surface of the reflection plate / acrylic plate / glass surface to remove the dirt. |
|
(2) |
Clean the device once in six months to one year to keep quality of the Color Temperature and Luminance. |
|
 |
| 【5】 |
Other Precautions |
 |
|
Handling the viewer needs the following precautions because it contains the parts using glass. |
|
(1) |
Do not add strong impact on the viewer |
|
(2) |
Do not put any heavy items on the surface of the viewer |
|